Desktop|中文
Home About Us
Products +
Company News Industry Trends Online Message Contact Us

Product Details

Automatic Dielectric Loss Tester - Yangzhou Darui

Dual-Frequency Anti-interference Dielectric Loss Tester - Yangzhou Darui

Published: 2020-08-06 10:22:30

产品价格:0.00

Views: 2922

Category: Dielectric Loss Tester

Product Description

Dielectric Loss Tester

Product Introduction:



Dielectric Loss Tester突破了传统的电桥测量方式VFD tech, MCU, auto conversion. 45/55Hz sine wave, up to 10kV, 50Hz filter. For transformer, CT/PT, bushing, capacitor, arrester D/L measurement.



Technical Specifications:



Accuracy: Cx ±(reading×1%+1pF)

tgδ: ±(reading×1%+0.00040)

Anti-interference: VFD, maintains accuracy under 200% interference

Capacitance range: internal HV: 3pF-60000pF/10kV, 60pF-1μF/0.5kV

External HV: 3pF-1.5μF/10kV, 60pF-30μF/0.5kV

Resolution: max 0.001pF, 4 digits

tgδ range: unlimited, res 0.001%, auto C/L/R ID.

Test current: 10μA-1A

Internal HV: set range 0.5-10kV

Max output current: 200mA

Ramping: continuous smooth adjustment

Test frequency: 45, 50, 55, 60, 65Hz single

45/55Hz, 55/65Hz, 47.5/52.5Hz auto dual VFD

Frequency accuracy: ±0.01Hz

External HV: max 1A at 40-70Hz for normal wiring

Max test current 10kV/1A at 40-70Hz for reverse wiring

CVT self-excitation LV output: 3-50V, 3-30A

Test time: ~40s, depends on mode

Input Power: 180-270VAC, 50Hz@1%, mains or generator

Computer interface: standard RS232

Printer: Weihuang A7 thermal micro printer

Ambient Temp: -10C to 50C

RH: <90%

Dimensions: 460x360x350mm

Weight: 28kg



Dielectric Loss Tester特征:



1. Uses complex current method for C, D/L measurement. High accuracy, easy automation.

2. Uses VFD tech to eliminate 50Hz interference, reliable under strong EM interference.

3. Large LCD with Chinese menu prompts for intuitive operation.

4. Easy operation, microcomputer controlled. Auto measurement after selecting mode.

5. Integrated design with std capacitor and HV supply for field use.

6. High accuracy for oil D/L measurement with std oil cup and test leads.

7. CVT self-excitation test, one measurement for C1, C2 capacitance and D/L.

8. Reverse test uses ivddv tech, eliminating unstable reverse data.

9. Reverse wiring low-voltage shielding function: performs non-disconnection 10kV reverse wiring dielectric loss measurement on C11 under 220kV CVT bus grounding conditions.

10. High-voltage dielectric loss measurement function: capable of conducting dielectric loss tests exceeding 10kV using high-voltage transformers or series resonance.

12. Ground protection: no HV without proper grounding. Overcurrent protection: safe during short circuit or breakdown.

13. Electric shock protection: instantly cuts HV if operator is shocked.



Precautions



1. Ground terminal must be reliably grounded.



2. Only safe when power off and selector at "Off".



3. Do NOT operate voltage selector during measurement.



4. Normal wiring: UH is HV. Reverse wiring: IX is HV. Keep HV cables at safe distance from ground.



5. Replace fuse only with specified rating (internal: 0.5A).



6. Use manufacturer-supplied cables for accuracy.


WeChat QR Code
💬
💬 Guestbook ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
Main Products: Dielectric Loss Tester, Transformer Ratio Tester, Loop Resistance Tester, High-Voltage Wireless Phase Detector, Insulation Resistance Tester, Partial Discharge Tester, Cable Fault Tester, DC Resistance Tester, etc.
Phone: 18952707000 (Manager Guan)Tel: 0514-88770377Email: 195214804@qq.com
Verification Code